Title: | Influence of Thermal Insulation on Conductive Heat Transfer through Roof Ceiling Construction |
Authors: | Suman, B M Srivastava, R K |
Keywords: | 2009 Thermal insulation Heat transfer Roof ceiling |
Issue Date: | 29-Sep-2011 |
Abstract: | This study determines influence of thermal insulation on conductive heat transfer through roof-ceiling construction when thermal insulation material was integrated to roofing system. Two pairs of two identical rooms, respective roofs were equipped with insulation to be tested; i) polystyrene and its identical pair with no insulation, and ii) fiberglass, and its pair with no insulation material . Roof with no insulation roof was considered as reference. Roof with polystyrene performed better than other roof insulation. |